NEWNIK SP501 Sphygmomanometer / Aneroid BP Monitor with Free

Stethoscope, Cuff & Carrying Case

MODEL : SP501


[su_row] [su_column size=”1/2″]

PRODUCT FEATURES

[su_list icon=”icon: square” icon_color=”#03b2ac” class=”icebag_fea”]

  • High Precision
  • Euro-type non-stop pin gauge
  • Adjustable zero position
  • Nylon Cuff with D-Ring
  • Clinically Validated & comes with stethoscope

[/su_list] [su_table]

Stages of blood pressure levels Systolic (mmhg) Diastolic (mmhg)

Hypertension

Stage 2

=>160

=>100

Stage 1

140-159

90-99

Pre-hypertension

120-139

80-89

Normal

<120

<80

[/su_table] [/su_column] [su_column size=”1/2″][su_custom_gallery source=”media: 1622,1623,1624,1625,1626″ link=”lightbox” title=”never”] [/su_column] [/su_row] [su_tabs class=”my-custom-tabs”] [su_tab title=”About blood pressure”] [su_list icon=”icon: check” icon_color=”#03b2ac”]

  • Measuring blood pressure by a doctor in the hospital tends to stimulate nervousness and may even create high blood pressure.
  • Blood pressure also varies in accordance with variety of conditions and so judgment is not possible on the basis of single measurement.
  • Regular home measuring lets you submit to your doctor a record of your measurement overtime.
  • This information may provide a better reference of what your blood pressure really is, and can help your doctor make important decisions about your diagnosis and treatment.

[/su_list] [/su_tab] [su_tab title=”Applying the cuff”] [su_list icon=”icon: check” icon_color=”#03b2ac”]

  • Place the cuff over the bare upper arm, wrap it with the tube pointing your palm and the artery mark over your main artery.
  • The edge of the cuff should be at approximately 2.0 to 3.0 cm above the inner side of the elbow joint. If the index line falls within the range of the arm circumference indicator, the cuff circumference is suitable, otherwise you may need a cuff with a different circumference.
  • Using the correct cuff size is important for an accurate reading.

[/su_list] [/su_tab] [su_tab title=”Measurement procedures”] [su_list icon=”icon: check” icon_color=”#03b2ac”]

  • Place the stethoscope head over the main artery, underneath the artery mark of cuff.
  • With the valve closed, press the bulb and continue pumping to a valve 20-30 mmHg above your normal blood pressure.
  • Open the valve to deflate the cuff gradually at a rate of 2-3 mmHg per second.
  • Record the onset of Korotkoff sound as the systolic pressure, and the disappearance of these sounds as diastolic pressure.
  • After measurement is completed, fully open the valve to release any remaining air in the cuff.

[/su_list] [/su_tab] [su_tab title=”Maintenance”] [su_list icon=”icon: check” icon_color=”#03b2ac”]

  • After measurement, wrap cuff around sphygmomanometer and bulb and store in the carrying case together with the stethoscope.
  • Always deflate cuff completely before storage.
  • Never touch the cuff fabric or parts with a sharp instruments.
  • Sphygmomanometer accuracy can be checked visually: simply be certain the needle rests within the area indicated by the red line under “0” when the unit is fully deflated. Under normal condition, it is recommended that calibration be completed every two years.
  • Clean the cuff with a slightly damp sponge or cloth. If necessary, it may be washed in cool water with mild soap. Remove bladder prior to washing. Rinse and air dry. Do not iron. Clean the bladder and bulb with a slightly damp sponge or cloth. To protect from cracking or discoloring, wipe with a soft cloth moistened with ethanol. Clean valve and gauge with a soft dry cloth.

[/su_list] [/su_tab] [su_tab title=”Safety information”] [su_list icon=”icon: check” icon_color=”#03b2ac”]

  • Newnik Aneroid Sphygmomanometer is exclusively designed for blood pressure measurement at the upper-arm.
  • Do not inflate more than 300mg.
  • Do not take your blood pressure for more than 3 minutes.
  • Wait for at least 2 minutes before repeated measurement.

[/su_list] [/su_tab] [su_tab title=”Specifications”] [su_list icon=”icon: check” icon_color=”#03b2ac”]

  • Measurement range: 0-300 mmHg
  • Accuracy : ±3 mmHg
  • Box Dimensions : 105(L)X70(W)X180(H)mm
  • Box Weight : 500 gm approx

[/su_list] [/su_tab] [/su_tabs]